[Date Prev][Date Next][Thread Prev][Thread Next]
[Author Index]
[Date Index]
[Thread Index]
[SQR-USERS Info]
[SQRUG Home Page]
Re: Warning while running SQR in an DB2/MVS environment
Michael,
Somewhere in your program, a SQR is attempting to
convert a string (whose value is 'EMP') into a
numeric variable (floating point DOUBLE PRECISION).
This could be moving an &variable to a #variable,
or moving a $variable to a #variable, or in reading
an &variable=number from the database or something
like that.
As a general rule, I would expect SQR to give a
better message. Does line 2416 mean anything in
any of your files?
Ray
> Hello all,
> Can anyone help me out with the following warning:
>
> LSCX109 **** NOTE ****
> Generated in STRTOD called from line 2416 of SQ287(SQ285) ,
> offset 001758
> String "EMP" does not contain a valid floating-point number.
>
> Thanks in advance,
>
> Michael K. Lee
> mlee@agconsult.com
> Consultant
> AG Consulting, an ADP Company
> http://www.agconsult.com
>
----------------------------------------------------------------------
Ray Ontko | Ray Ontko & Co | "Time for a new signature line."
rayo@ontko.com | Richmond, In | See us at http://www.ontko.com/